---------------------產品詳情-------------------------
10D40-3CGA1AA0A5AA+M1
Endress + Hauser 10D40-3CGA1AA0A5AA+M1
Electromagnetic flowmeter
10D40-10Q9/101
Endress Hauser 10 D40
3 Liner: Polyamide
C Process Connection: PN16, EN1092-1 (DIN2501)
G Electrodes: 14435/316L bullet nose
A Calibration: 05%
1 Additional Test, certificate: w/o
A Approval: Non-hazardous area
A Housing: Compact Alu, IP67 NEMA4X
0 Cable, Remote Version: Not used
A Cable Entry: Gland M20
5 Power Supply; Display: 20-28VAC / 11-40VDC; 2-line, push buttons
A Adjustment; Software Feature: Factory setup; basic version
A Output, Input: 4-20mA HART + pulse passive
M1 >Mounting kit enclosed steel zinc coated threaded bolt, nut, washer, EPDM flange seal
Details: Language: English
Assign line 1: Volume flow
Assign line 2: Totalizer 1
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 20 mA: dm3/min
Time constant: 100000 s
Assign pulse output: Volume flow
Pulse value (per pulse): 150000 dm3
Pulse width: ms
Output signal: Passive – negative
Failsafe mode current/pulse output: Min value
Assign totalizer 1: Volume flow
Unit totalizer 1: dm3
---------------------其他型號-------------------------
10D65-6CGA1AA0A5AA+M1
Endress + Hauser 10D65-6CGA1AA0A5AA+M1
6 Liner: Polyamide, ACS Drinking water approval
C Process Connection: PN16, EN1092-1 (DIN2501)
G Electrodes: 14435/316L bullet nose
A Calibration: 05%
1 Additional Test, certificate: w/o
A Approval: Non-hazardous area
A Housing: Compact Alu, IP67 NEMA4X
0 Cable, Remote Version: Not used
A Cable Entry: Gland M20
5 Power Supply; Display: 20-28VAC / 11-40VDC; 2-line, push buttons
A Adjustment; Software Feature: Factory setup; basic version
A Output, Input: 4-20mA HART + pulse passive
M1 >Mounting kit enclosed steel zinc coated threaded bolt, nut, washer, EPDM flange seal
Details: Language: English
Assign line 1: Volume flow
Assign line 2: Totalizer 1
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 20 mA: dm3/min
Time constant: 100000 s
Assign pulse output: Volume flow
Pulse value (per pulse): 500000 dm3
Pulse width: ms
Output signal: Passive – negative
Failsafe mode current/pulse output: Min value
Assign totalizer 1: Volume flow
Unit totalizer 1: dm3
10D40-4CGA1AA0A5AA+M1
Endress + Hauser 10D40-4CGA1AA0A5AA+M1
4 Liner: Polyamide, NSF 61 Drinking- + warm water approval
C Process Connection: PN16, EN1092-1 (DIN2501)
G Electrodes: 14435/316L bullet nose
A Calibration: 05%
1 Additional Test, certificate: w/o
A Approval: Non-hazardous area
A Housing: Compact Alu, IP67 NEMA4X
0 Cable, Remote Version: Not used
A Cable Entry: Gland M20
5 Power Supply; Display: 20-28VAC / 11-40VDC; 2-line, push buttons
A Adjustment; Software Feature: Factory setup; basic version
A Output, Input: 4-20mA HART + pulse passive
M1 >Mounting kit enclosed steel zinc coated threaded bolt, nut, washer, EPDM flange seal
Details: Language: English
Assign line 1: Volume flow
Assign line 2: Totalizer 1
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 20 mA: dm3/min
Time constant: 100000 s
Assign pulse output: Volume flow
Pulse value (per pulse): 150000 dm3
Pulse width: ms
Output signal: Passive – negative
Failsafe mode current/pulse output: Min value
Assign totalizer 1: Volume flow
Unit totalizer 1: dm3
10D50-7CGA1AA0A4AA+M1
Endress + Hauser 10D50-7CGA1AA0A4AA+M1
7 Liner: Polyamide, WRAS BS6920 Drinking water approval
C Process Connection: PN16, EN1092-1 (DIN2501)
G Electrodes: 14435/316L bullet nose
A Calibration: 05%
1 Additional Test, certificate: w/o
A Approval: Non-hazardous area
A Housing: Compact Alu, IP67 NEMA4X
0 Cable, Remote Version: Not used
A Cable Entry: Gland M20
4 Power Supply; Display: 85-250VAC; 2-line, push buttons
A Adjustment; Software Feature: Factory setup; basic version
A Output, Input: 4-20mA HART + pulse passive
M1 >Mounting kit enclosed steel zinc coated threaded bolt, nut, washer, EPDM flange seal
Details: Language: English
Assign line 1: Volume flow
Assign line 2: Totalizer 1
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 20 mA: dm3/min
Time constant: 100000 s
Assign pulse output: Volume flow
Pulse value (per pulse): 250000 dm3
Pulse width: ms
Output signal: Passive – negative
Failsafe mode current/pulse output: Min value
Assign totalizer 1: Volume flow
Unit totalizer 1: dm3
---------------------優勢品牌-------------------------
Anderson-Negele耐格,HBM傳感器,Bürkert寶德,HAUG豪格,EGE,PULS普爾世,TWK,ELEKTROR風機,
EMRAX 電機,bronkhorst流量控制器, wandres 劍刷,HAUBER Elektronik霍伯納,BUEHLER BüHLER 傳感器,
staiger電磁閥 ,loval加熱器,microsonic超聲波傳感器 ,Steuber ,Spieth 聯軸器 ,VESTA 電磁閥線圈,
TECNA 平衡器,NSI比利時鍵盤,HB Products位移傳感器 ,SPECK 離心泵 密封件,DELO點膠頭 ,
AirCom壓力計MHA-A5P ,VESTER傳感器 ,GRAS麥克風 ,Kalinsky 傳感器,
ALPHA-CURE紫外線,SCHIEDRUM HYDRAULIK流量閥,Mazurczak 加熱電阻器,
AVS ROEMER 電磁閥 接頭,Quintest 噴碼機,Dietz Sensortechnik 器等,歡迎詢價!
詢價請直接找
----------------------------------------------
如有咨詢,歡迎隨時聯系我!
(同微信號)
深圳市仕達威實業有限公司
Shenzhen StarView Industrial Co Ltd.
手機: (同微信號)
郵箱: sales
: 2038 號愛華大廈 609 室 郵編: 518028
Aihua Building 609 room, Shennan Middle of the No.2038, Shenzhen
仕達威18年行業經驗,歡迎詢價采購!
| 仟漁 |
同類優質產品
會員登錄X請輸入賬號 請輸入密碼 請輸驗證碼 提示X您的留言已提交成功!我們將在第一時間回復您~
歐亞貿易網 設計制作,未經允許翻錄必究 .Copyright(C) http://m.78511280.cc,All rights reserved. 以上信息由企業自行提供,信息內容的真實性、準確性和合法性由相關企業負責,歐亞貿易網對此不承擔任何保證責任。溫馨提示:為規避購買風險,建議您在購買產品前務必確認供應商資質及產品質量。 |




所有評論僅代表網友意見,與本站立場無關。