Linkam顯微鏡熱臺(tái)
Standard Features
Temperature range -196° to 600°C 100 ohm platinum resistor sensor. 1/10th Din class A accurate to 0.1°C Temperature stability <0.1°c temperature="" response="" between="" 0="" and="" 2="" seconds="" silver="" heating="" block="" for="" high="" thermal="" conductivity="" direct="" injection="" of="" the="" coolant="" into="" the="" silver="" block="" sample="" mounted="" directly="" on="" the="" silver="" block="" sample="" area="" 22="" mm="">0.1°c>
Objective lens minimum working distance 4.5mm Condenser lens minimum working distance12.5mm A variety of windows can be fitted for different applications Can be used with all microscope techniques Gas tight chamber for atmospheric control Water cooling of stage body for high temperature work (>300°C) Side loading without removing the lid Mounts directly on microscope table or substage Vacuum tight option
| Application | Stage | Key Features |
| General Heating/Freezing stage Available as a LIQUID CRYSTAL STAGE with special carrier. | ![]() THMS 600 | 16 mm X,Y sample manipulators Sample side loading without removing the stage lid Clamps directly to the microscope substage for stability Stage body size - 137 x 92 x 22 mm Light aperture - 2.4mm ?Single ultra thin lid window - 0.17mm Sample area 22mm High thermal conductivity silver block for fast response and cooling Temperature range -196° to 600°C Temperature stability and sensor accuracy +/- 0.1°C |
| Designed for FTIR | ![]() FTIR 600 | Temperature range -196°C to 600°C Wide angle tapered hole in block for maximum IR transmission Range of IR transparent windows available |
| Designed for Freeze Drying Vacuum studies | ![]() FDCS 196 | FDCS 196 Freeze Drying Vacuum Stage 16 mm X,Y sample manipulators which can still be used under vacuum Clamps directly to the microscope substage for stability Light aperture - 2.4 mm ? Single ultra thin lid window - 0.3mm Capable of 10-3 mBar High thermal conductivity silver block for fast response and cooling Temperature range -196° to 400°C (under vacuum. Up to 600°C at atmospheric.) Temperature stability and sensor accuracy +/- 0.1°C |
| Low cost, optical bench | ![]() HFS 91 | Temperature range -196° to 600°C All features as above Low cost heating and freezing stage Can be vertically mounted Ideal for optical bench Stage body size - 104 x 92 x 22 mm Centre quartz window - 2.4 mm ? |
| Polyer and Liquid Crystal Large area Heating/Freezing stageAvailable as a LIQUID CRYSTAL STAGE with special carrier. | ![]() LTS 350 | Temperature Range -196°C to 350 °C Sample area of 38 mm x 62 mm 15mm by 15mm X, Y manipulation as standard Sample holder for standard 76 by 26mm microscope slides Gas tight chamber for atmospheric control Swing out lid for easy sample loading 100 ohm platinum sensor 1/10th din standard class A Temperature stability & accuracy to < 0.1°c="" inner="" lid="" to="" increase="" temperature="" stability="" direct="" injection="" of="" coolant="" into="" block="" maximum="" heating="" cooling="" rate="" of="" 30°c/min="" response="" time="" of=""><1 second="" at="" 5°c/min="" at="" 50°c="" objective="" lens="" minimum="" working="" distance="" 6mm="" condenser="" lens="" minimum="" working="" distance="">1> |